35, Millbrook Heights, Dinas Powys
Commencement Date
05/01/2017
Decision Date
19/01/2017
Completion Date
26/07/2017
Valid Date
20/12/2016
Proposal
Single storey extension, garage conversion and porch to front of house
Decision
Approved Conditionally
Decision Date
19/01/2017

Code Condition Details
ns Structural calculations are required to be deposited for the retaining walls, foundations suspended reinforced floor.
ns Full construction specification required.
ns Indicate roof joists sizes, centres and grade.
ns Provide details of the lintel manufacturer and type of lintels to be used.
ns Wall ties must be provided at 900mm centres horizontally, 450mm centres vertically and 300mm centres vertically at the reveals of any openings.
ns The walls should be strapped to the roof joists using 30x5mm galvanised mild steel tension straps at least 1.2m long at 2.0 metre centres.
ns The minimum U value for the extension pitched roof - insulation at ceiling level is 0.16 W/m2K increase the insulation thickness.
ns The minimum U value for the extension wall element is 0.28 W/m2K increase the insulation thickness.
ns The minimum U value for the extension floor element is 0.22 W/m2K increase the insulation thickness.
ns Provide a layout plan showing the full details of the drainage system including runs, falls, invert levels, access and ventilation. Full details of manhole construction and size.
ns The proposed electrical installation is to be installed with BS 7671:2001 and the latest IEE regulations and is to be inspected and tested in accordance with those documents.
ns Installation and testing certificates are to be provided for the electrical installation. Copies of these certificates are to be provided to the Building Control Department for their records.
ns Provide full details of the glazing to the critical locations.
ns The guarding to the internal balcony should be at least 1100mm in height and provide details of fixing.
ns Provide smoke detectors in the hall/stair landing and playroom area and an interlinked heat detector in the kitchen.
ns The habitable rooms should be ventilated by both, a ventilation opening at least equal to 1/20th of the floor area of the room and, by a background ventilation opening equivalent to 5000mm2.
ns The proposed pitched roof requires effective cross ventilation above the insulation. This should be equivalent in area to a continuous 10mm air gap on two opposite sides of the roof.
ns The cavities in the external wall must be effectively sealed at roof level.
ns The elements of structure require a fire resistance of half an hour.
ns The ventilation extract rate to the proposed utility room is to be 30 l/s. Minimum high rate to be 8 l/s.
ns The ventilation extract rate to the proposed WC is to be 6 l/s.
ns Supply a section plan through the steps showing the pitch, risers, goings headroom and heights of handrails.
ns The dining room/lounge, playroom and study should have a window or rooflight at least 733 mm high and 450mm wide when in the open position confirmation is required.