Building Control Application details for 2015/0037/BR
- Building Regs No.
- 2015/0037/BR
- Application Type
- Building Regulations-Full Plan
- Planning Ref
- 2014/01213/FUL
- Decision
- Approved Conditionally
- Location
- 119, Westward Rise, Barry
- Commencement Date
- 15/05/2015
- Decision Date
- 22/01/2015
- Completion Date
- 08/09/2015
- Valid Date
- 20/01/2015
- Proposal
- Conversion of un-used garage into a habitable room (office), with new small extension to existing house
- Decision
- Approved Conditionally
- Decision Date
- 22/01/2015
Code | Condition Details |
---|---|
ns | Following examination of your submitted drawings and inspection of the map of sewers, it would appear that the proposal will be built over or within 3 metres of a public drain/sewer. You are therefore required to consult with the owner of the drain/sewer or the statutory undertaker. |
ns | The minimum U value for the extension wall element is 0.21 W/m2K. Increase the insulation thickness or provide a U value calculation. |
ns | The minimum U value for the extension floor element is 0.18W/m2K. Increase the insulation thickness or provide a U value calculation. |
ns | The minimum U value for the extension pitched roof - insulation at ceiling level is 0.15 W/m2K. Increase the insulation thickness or provide a U value calculation. |
ns | Specify the full details of the proposed heating appliances to be installed in the building. |
ns | Indicate the rafter & ceiling joists sizes and centres. |
File name | Created date | |
---|---|---|
Building Control Documents | ||
Decision Notice | 26/01/2015 | |
Comp Cert | 08/09/2015 |