Welcome to the
Vale of Glamorgan Council

Building Control Application details for 2014/0768/BR



Building Regs No.
2014/0768/BR
Application Type
Building Regulations-Full Plan
Planning Ref
2014/00896/FUL
Decision
Cancelled (see comments)
Location
The Links, Penylan Road, Aberthin
Commencement Date
-
Decision Date
24/11/2014
Completion Date
-
Valid Date
06/11/2014
Proposal
Alteration & extension of 2 storey dormer bungalow
Decision
Cancelled (see comments)
Decision Date
24/11/2014

Code Condition Details
ns Structural calculations & details are required to be deposited for the following: a. Steel posts b. Valley beams c. Ridge beams d. Stanchions & bases e. Glulam beams f. Steel stairs
ns Provide installation and test certificates for the gas appliance.
ns Bedrooms 4 & 5 require escape windows as they are inner rooms at least 733 mm high and 450mm wide when in the open position for mean of escape.
ns A percolation test should be carried out on site in order to determine the size and number of soakaways required. The test must be carried out in accordance with the Building Research Establishment Digest number 365.
ns The proposed electrical installation is to be installed by a competent person registered under the Governments competent person scheme. Either, BRE Certification Ltd, BSI, ELECSA Ltd, NAPIT Certification Ltd or NICEIC Certifications Services Ltd.
ns Installation and testing certificates are to be provided for the electrical installation. Copies of these certificates are to be provided to the Building Control Department for their records.
ns Provide a layout plan showing the full details of the drainage system including runs, falls, invert levels, access and ventilation. Full details of the manhole constructionsize and flow rate calculations are also required.
ns The elements of the structure a fire resistance of half an hour.
ns The cavities in the external wall must be effectively sealed at roof level.
ns Consequential improvements are required to the existing dwelling. These could have an effect on the existing property and must be adhered to. Firstly note the comments in AD L1B(Wales) Section 4, page 15. For details on 'consequential improvement measures' see the following references: Extension less than 10m2 refer to pages 15 & 16, paras 4.2.1.&4.2.4. of you proposals to meet the criteria. To access the document please go to:- http://wales.gov.uk/topics/planning/?lang=en