Welcome to the
Vale of Glamorgan Council

Building Control Application details for 2014/0660/BR



Building Regs No.
2014/0660/BR
Application Type
Building Regulations-Full Plan
Planning Ref
2014/00854/FUL
Decision
Approved Conditionally
Location
7, Rutland Close, Highlight Park, Barry
Commencement Date
18/09/2014
Decision Date
26/09/2014
Completion Date
13/01/2021
Valid Date
19/09/2014
Proposal
Single storey front, side & rear extension
Decision
Approved Conditionally
Decision Date
26/09/2014

Code Condition Details
ns The ventilation extract rate to the proposed utility room is to be 30l/s. Minimum high rate to be 8l/s.
ns The minimum U value for the extension wall element is 0.21 W/m2K. Increase the insulation thickness or provide a U value calculation.
ns Provide a layout plan showing the full details of the drainage system including runs, falls, invert levels, access and ventilation. Full details of manhole construction and size and flow rate calculations are also required.
ns The proposed electrical installation is to be installed by a competent person registered under the Governments competent person scheme. Either, BRE Certificate Ltd, BSI, ELECSA Ltd, NAPIT Certification Ltd or NICEIC Certifications Services Ltd.
ns Installation and testing certificates are to be provided for the electrical installation. Copies of these certificates are to be provided to the Building Control Department for their records.
ns Provide the full manufacturers details and span tables for the lintels.
ns Consequential improvements are required to the existing dwelling. These could have an effect on the existing property and must be adhered to. Firstly note the comments in AD L1B (Wales) Section 4, page 15. For details on 'consequential improvement measures' see the following refereneces: Extensions less than 10m2 refer to pages 15 & 16 paras 4.2.1 & 4.2.4. for extensions over 10m2 refer to pages 15 & 16 paras 4.2.2 & 4.2.4. Please provide details of you proposals to meet the criteria. To access the document please go to:- http://wales.gov.uk/topics/planning/?lang=en
  File name Created date
Building Control Documents
You are here:  