Building Control Application details for 2014/0641/BR



Building Regs No.
2014/0641/BR
Application Type
Building Regulations-Full Plan
Planning Ref
2014/00804/FUL
Decision
Approved Conditionally
Location
24, St. Davids Crescent, Penarth
Commencement Date
05/03/2015
Decision Date
19/09/2014
Completion Date
12/02/2016
Valid Date
10/09/2014
Proposal
Rear single storey extension to provide living space, kitchen & cloakrooms. Loft conversion for 2 No. bedrooms & bathroom. New roof
Decision
Approved Conditionally
Decision Date
19/09/2014

Code Condition Details
ns Following examination of your submitted drawings and inspection of the map of sewers, it would appear that the proposal will be built over or within 3 metres of a public drain/sewer. You are, therefore, required to consult with the owner of the drain/sewer or the statutory undertaker.
ns It has been assumed that the structural calculations deposited with your application have been designed and verified by a qualified structural engineer. On this basis, the design has been accepted.
ns Due to the close proximity of the adjoining boundary/wall/buildings you should consult the adjoining owners with regards to your proposal.
ns Doors DF 01, 02, 03 & DS 02, 03 to be FD20.
ns Consequential improvements are required to the existing dwelling. These could have an effect on the existing property and must be adhered to. Firstly, note the comments in AD L1B (Wales) Section 4, page 15. For details on 'consequential improvement measures' see the following references: Extensions less than 10m2 refer to pages 15 & 16, paras. 4.2.1 & 4.2.4. For extensions over 10m2 refer to pages 15 & 16, paras. 4.2.2. & 4.2.4. Please provide details of your proposals to meet the criteria. To access the document please go to: http://wales.gov.uk/topics/planning/?lang=en.
ns The ventilation extract rate to the proposed kitchen is to be 30 l/s (adjacent to hob) or 60 l/s (elsewhere). Minimum high rate to be 13 l/s.
ns The ventilation extract rate to the proposed bathroom/ensuite is to be 15 l/s. Minimum high rate to be 8 l/s.
ns The ventilation extract rate to the proposed laundry room is to be 30 l/s. Minimum high rate to be 8 l/s.
ns The proposal has been identified as being in an area which may be affected by Radon. Once the work has been completed, it is advisable that the property is tested in accordance with National Radiological Protection Board's recommendations. Any cracks in the floor slab, walls or at service entries are to be suitably sealed with flexible sealers. A Radon tray is to be provided at GF d.p.c. level.
ns The proposed electrical installation is to be installed by a competent person registered under the Government's competent person scheme. Either BRE Certification Ltd., BSI, ELECSA Ltd., NAPIT Certification Ltd. or NICEIC Certifications Services Ltd.
ns Installation and testing certificates are to be provided for the electrical installation. Copies of these certificates are to be provided to the Building Control Department for their records.
ns The stairway and landing should have headroom of at least two metres measured vertically from the pitch line.
ns The tapered treads must have a minimum going of 50 mm. Consecutive tapered treads must have a uniform going.
ns Provide interlinked smoke detectors with battery backup where new habitable rooms are created in the existing hall/stair and landing and a heat detector in the kitchen.
ns Provide the full manufacturer's details and span tables for the lintels.
ns Specify the full details of the proposed heating appliances to be installed in the building.
ns The foundations to the existing building must be exposed for inspection prior to the commencement of work on site.